Zgryźliwość kojarzy mi się z radością, która źle skończyła.
//-->.pos {position:absolute; z-index: 0; left: 0px; top: 0px;}Installation InstructionsCompactLogix ControllersCatalog Numbers 1768-L43, 1768-L43S, 1768-L45, 1768-L45STopicImportant User InformationAbout CompactLogix ControllersVerify CompatibilityRequired System ComponentsClearance RequirementsModule PlacementInstall the ControllerPanel Mount the ControllerMount the Controller on a DIN RailConfirm the InstallationConnect to the ControllerConfigure a Communication DriverInsert or Remove a CompactFlash CardInstall Controller FirmwareRemove a 1768 or 1769 Module from the DIN RailStatus IndicatorsSafety Status Indicators (1768-L43S and 1768-L45S Controllers only)Clear a Major FaultClear a Nonrecoverable FaultTroubleshoot a Nonresponsive ModuleTroubleshoot System PowerSpecificationsAdditional ResourcesPage2667789101013141418182123252627272832362CompactLogix ControllersImportant User InformationSolid state equipment has operational characteristics differing from those of electromechanicalequipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls(publicationSGI-1.1available from your local Rockwell Automation sales office or online athttp://literature.rockwellautomation.com)describes some important differences between solid stateequipment and hard-wired electromechanical devices. Because of this difference, and also because ofthe wide variety of uses for solid state equipment, all persons responsible for applying this equipmentmust satisfy themselves that each intended application of this equipment is acceptable.In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damagesresulting from the use or application of this equipment.The examples and diagrams in this manual are included solely for illustrative purposes. Because of themany variables and requirements associated with any particular installation, Rockwell Automation, Inc.cannot assume responsibility or liability for actual use based on the examples and diagrams.No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits,equipment, or software described in this manual.Reproduction of the contents of this manual, in whole or in part, without written permission of RockwellAutomation, Inc., is prohibited.Throughout this manual, when necessary, we use notes to make you aware of safety considerations.WARNINGIdentifies information about practices or circumstances that can cause an explosion ina hazardous environment, which may lead to personal injury or death, propertydamage, or economic loss.Identifies information that is critical for successful application and understanding ofthe product.Identifies information about practices or circumstances that can lead to personalinjury or death, property damage, or economic loss. Attentions help you identify ahazard, avoid a hazard and recognize the consequences.IMPORTANTATTENTIONSHOCK HAZARDLabels may be on or inside the equipment, for example, drive or motor, to alert peoplethat dangerous voltage may be present.BURN HAZARDLabels may be on or inside the equipment, for example, drive or motor, to alert peoplethat surfaces may reach dangerous temperatures.Publication1768-IN004D-EN-P - December 2009CompactLogix Controllers3Environment and EnclosureATTENTIONThis equipment is intended for use in a Pollution Degree 2 industrial environment,in overvoltage Category II applications (as defined in IEC publication 60664-1), ataltitudes up to 2000 m (6562 ft) without derating.This equipment is considered Group 1, Class A industrial equipment according toIEC/CISPR Publication 11. Without appropriate precautions, there may bedifficulties with electromagnetic compatibility in residential and otherenvironments due to conducted as well as radiated disturbances.This equipment is supplied as open-type equipment. It must be mounted withinan enclosure that is suitably designed for those specific environmentalconditions that will be present and appropriately designed to prevent personalinjury resulting from accessibility to live parts. The enclosure must have suitableflame-retardant properties to prevent or minimize the spread of flame, complyingwith a flame spread rating of 5VA, V2, V1, V0 (or equivalent) if non-metallic. Theinterior of the enclosure must be accessible only by the use of a tool. Subsequentsections of this publication may contain additional information regarding specificenclosure type ratings that are required to comply with certain product safetycertifications.In addition to this publication, see:•Industrial Automation Wiring and Grounding Guidelines, RockwellAutomation publication1770-4.1,for additional installationrequirements.•NEMA Standards 250 and IEC 60529, as applicable, for explanations ofthe degrees of protection provided by different types of enclosure.Publication1768-IN004D-EN-P - December 20094CompactLogix ControllersEuropean Hazardous Location ApprovalConsider the following if you install a 1768-L43S or 1768-L45Scontroller in a European Zone 2 location.European Zone 2 Certification (The following applies when the product bears theEX marking.)This equipment is intended for use in potentially explosive atmospheres as defined byEuropean Union Directive 94/9/EC and has been found to comply with the Essential Healthand Safety Requirements relating to the design and construction of Category 3 equipmentintended for use in Zone 2 potentially explosive atmospheres, given in Annex II to thisDirective.Compliance with the Essential Health and Safety Requirements has been assured bycompliance with EN 60079-15 and EN 60079-0.WARNING•This equipment must be installed in an enclosure providing at least IP54protection when applied in Zone 2 environments.•This equipment shall be used within its specified ratings defined byAllen-Bradley.•Provision shall be made to prevent the rated voltage from beingexceeded by transient disturbances of more than 40% when applied inZone 2 environments.•This equipment is not resistant to sunlight or other sources of UVradiation.•Secure any external connections that mate to this equipment by usingscrews, sliding latches, threaded connectors, or other means providedwith this product.•Do not disconnect equipment unless power has been removed or thearea is known to be nonhazardous.General Safety Information for 1768-L43S and 1768-L45S ControllersATTENTIONPersonnel responsible for the application of safety-related programmableelectronic systems (PES) shall be aware of the safety requirements in theapplication of the system and shall be trained in using the system.Publication1768-IN004D-EN-P - December 2009CompactLogix Controllers5North American Hazardous Location ApprovalThe following information applies whenoperating this equipment in hazardouslocations.Products marked "CL I, DIV 2, GP A, B, C, D" are suitable foruse in Class I Division 2 Groups A, B, C, D, HazardousLocations and nonhazardous locations only. Each product issupplied with markings on the rating nameplate indicatingthe hazardous location temperature code. Whencombining products within a system, the most adversetemperature code (lowest "T" number) may be used to helpdetermine the overall temperature code of the system.Combinations of equipment in your system are subject toinvestigation by the local Authority Having Jurisdiction atthe time of installation.Informations sur l’utilisation de cetéquipement en environnements dangereux.Les produits marqués "CL I, DIV 2, GP A, B, C, D" neconviennent qu'à une utilisation en environnements deClasse I Division 2 Groupes A, B, C, D dangereux et nondangereux. Chaque produit est livré avec des marquages sursa plaque d'identification qui indiquent le code detempérature pour les environnements dangereux. Lorsqueplusieurs produits sont combinés dans un système, le code detempérature le plus défavorable (code de température le plusfaible) peut être utilisé pour déterminer le code detempérature global du système. Les combinaisonsd'équipements dans le système sont sujettes à inspection parles autorités locales qualifiées au moment de l'installation.AVERTISSEMENTWARNINGEXPLOSION HAZARD -• Do not disconnect equipment unlesspower has been removed or thearea is known to be nonhazardous.• Do not disconnect connections tothis equipment unless power hasbeen removed or the area is knownto be nonhazardous. Secure anyexternal connections that mate tothis equipment by using screws,sliding latches, threadedconnectors, or other meansprovided with this product.• Substitution of components mayimpair suitability for Class I,Division 2.• If this product contains batteries,they must only be changed in anarea known to be nonhazardous.RISQUE D’EXPLOSION –• Couper le courant ou s'assurerque l'environnement est classénon dangereux avant dedébrancher l'équipement.• Couper le courant ou s'assurerque l'environnement est classénon dangereux avant dedébrancher les connecteurs. Fixertous les connecteurs externesreliés à cet équipement à l'aidede vis, loquets coulissants,connecteurs filetés ou autresmoyens fournis avec ce produit.• La substitution de composantspeut rendre cet équipementinadapté à une utilisation enenvironnement de Classe I,Division 2.• S'assurer que l'environnement estclassé non dangereux avant dechanger les piles.Preventing Electrostatic DischargeATTENTIONThis equipment is sensitive to electrostatic discharge, which can cause internaldamage and affect normal operation. Follow these guidelines when you handlethis equipment:•Touch a grounded object to discharge potential static.•Wear an approved grounding wriststrap.•Do not touch connectors or pins on component boards.•Do not touch circuit components inside the equipment.•Use a static-safe workstation, if available.•Store the equipment in appropriate static-safe packaging when not in use.Publication1768-IN004D-EN-P - December 2009zanotowane.pl doc.pisz.pl pdf.pisz.pl hannaeva.xlx.pl